7 x 19 Strand

 

Most Flexible

Lowest Break Load

 

1 x 19 Strand

 

Rigid Cable

High Break Load

Lov Stretch Characteristics

Compact Strand

 

Most Rigid Cable

Low Stretch

Highest Tensile Strength

WEB: www.inoxline.dk Mail: sh@inoxline.dk Telefon: 0045-7020 9840. Skype: Inoxline.dkl

Adresse: Danevirkevej 6,St. TV, DK 7000 Frederici

Loading of stainless cables:

 

Stainless steel cable will begin to distort at around 50% of its breaking load.

 

For this reason it's recommended to apply a factor of safety of 2, and not to load the cables to more than 50% of their breaking loads.

Minimum Break Loads for Stainless Cables

Cable Diameter

mm

4

6

8

10

12

16

19

22

26

Macalloy Fork Size

 

M10

M10

M12

M16

M20

M24

M24

M30

M36

7 x 19 Strand

kN

36

69

108

156

249

364

501

660

912

Min.1 x 19 Strand

kN

48

91

143

207

330

483

665

875

1209

Compact Strand

kN

0,75

1,4

2,2

3

4,8

7,1

9,4

12,5

16,7

 

Galvanic isolation:

 

When stainless steel system is joined to carbon steel gusset plates, it is recommended to use the Macalloy isolation system.

 

Maximum Length of Individual Bar Lengths

Diameter

Stainless Steel

Carbon

Galvanised

M10 - M16

6,0 m

11,95 m

6,0 m

M20 - M30

6,0 m

11,95 m

8 m

M36 - M100

6,0 m

11,95 m

11,95 m