Macalloy Compression Struts

Macalloy supply a range of 3 types of Compression Struts:

 

1: Architectural Compression Strut

 

2: Standard Compression Strut

 

3: Fixed End Compression Strut.

Table 1: CHS-Outher Diameter and Wall Thickness

System Ref

 

M12

M16

M20

M24

M30

M36

M42

M48

M56

M64

M76

M85

M90

M100

Carbon CHS OD

mm

33,7

42,4

48,3

60,3

76,1

88,9

114,3

139,9

168,3

193,7

219,1

244,5

273,0

323,9

Carbon CHS Wall Thickness

mm

4

5

5

5

5

5

6,3

10

10

10

12,5

16

16

16

Stainless CHS OD

mm

33,4

42,16

48,3

60,33

73,07

 

 

 

 

 

 

 

 

 

Stainless CHS Wall Thickness

mm

4,5

4,85

5,08

5,16

 

 

 

 

 

 

 

 

 

 

Contact Inoxline for details

Macalloy Fixed End Compression Strut

Fixed End Compression Strut is a completely new and cost-effective compression rod with fixed CHS Fork Ends.

We supply only the forks to be welded on standard pipes.

 

At assembly the pipe and the forks are placed in correct position, and then either stabled or welded in place.

WEB: www.inoxline.dk Mail: sh@inoxline.dk Telefon: 0045-7020 9840. Skype: Inoxline.dkl

Adresse: Danevirkevej 6,St. TV, DK 7000 Frederici

Macalloy Architectural och Standard Compression Strut

 

 

Standar - og Architectural Compression Strut are both equipped with Macalloys adjustable fork system.

 

These two Compression Struts have the same properties, but Architectual is more elegant.

 

Table 2: Capacity and Length of Architectural og Standard Compression Strut

 

System Ref

 

M12

M16

M20

M24

M30

M36

M42

M48

M56

M64

M76

M85

M90

M100

Maximum compressive capacity to EN 1993 standard

kN

14,0

28,1

44,7

69,3

121,6

189,6

274,0

369,7

530,0

728,7

1063,9

1395,3

1588,6

2031,3

Maximum pin to pin length on EN 1993 standard

mm

2369

2663

2671

3105

3357

3367

4498

6397

7097

7420

8188

9323

10291

116796

Maximum length are based on the strut taking the maximum compressive capacity. For lower compressive loads longer lengths can be used.